Rainfall Collection Calculator
Estimate potential rainwater volume from a horizontal catchment area, rainfall depth and an editable collection factor.
How the result changes
Only horizontal catchment area changes; all other inputs stay at your current values. The line illustrates the formula across the shown range. This is not a forecast of real-world outcomes.
About this calculation
Estimate how much water a rain event could contribute to a tank from a chosen catchment footprint. Enter horizontal catchment area in square meters, rainfall depth in millimeters and an assumed percentage actually collected. The tool reports liters and cubic meters. It models volume, not water quality, storage capacity or whether a collection system is permitted at your location.
Formula
V (L) = A_horizontal (m²) × R (mm) × η/100; V (m³) = V (L)/1000
Worked example
With Horizontal catchment area: 100 m², Rainfall depth: 20 mm, Assumed collection factor: 80 %, potential collected volume is 1,600 L.
Inputs and calculation
A millimeter of rain across a square meter represents a liter of water before losses. Multiply the horizontal area by rainfall depth, then apply the editable collection factor for runoff and system losses. Use horizontal projected area rather than the sloped roof sheet area, because rainfall depth is measured vertically against horizontal ground. The U.S. Geological Survey illustrates this relationship with roof-area rainfall volumes.
Worked example
A 100 m² horizontal catchment receiving 20 mm of rain gets 2,000 L in the ideal geometric calculation. With an 80% assumed collection factor, modeled tank inflow is 1,600 L, or 1.6 m³. The factor is an illustrative input; actual capture depends on the roof, gutters, first-flush diversion and the storm’s timing.
Reading the result
The result can support a comparison between tank capacity and a typical storm or between alternative roof catchments. It does not mean all that water will be usable: a nearly full tank overflows, while a dry or partially connected roof may yield less. Choose a factor supported by your own installation or treat several factors as scenarios. Seasonal rainfall totals are not equivalent to one uninterrupted storm.
Scope and common mistakes
Do not use the estimate to infer safe drinking water or stormwater compliance. Collection hardware, contamination, filtration and local rules require separate evaluation. If roof planes drain to different outlets, include only the catchment connected to the tank. If rainfall depth is supplied in inches, convert to millimeters before entering it.
Common questions
What should I check before using the rainfall collection calculator result?
Check that roof area is the horizontal projection served by the actual gutters and that rainfall is in millimeters. A collection factor below full capture should be an explicit assumption, not mistaken for a universal efficiency. Compare the liters result with available empty tank space.
Sources and references
Inputs
- Horizontal catchment area (m²)
- Rainfall depth (mm)
- Assumed collection factor (%)